Technical specifications
ColoursBlack, White, Blue & Grey.
Power SourceAC 240V 50Hz
Module2 (1 Switch - 16 Amps)
Max LoadGeyser Upto 2500W (~20 liter Capacity)
Self Consumption~1.6W
Wireless StandardIEEE 802.11 b/g/n
Operating Temp-10°C to +55°C
Dimension88mm x 88mm x 43mm
Enclosure MaterialABS (FR Grade)
Net Weight0.19kg
Remote control distance22 ft
Wiring drawing
Wiring drawing for 1 Switch
TerminalMeaning
NNeutral
P1Phase 1 UPS/EB
P2Phase 2 EB
HHigh-Load
  • Type 1: Single Power Source (EB or UPS and Common Neutral): The phases for EB and UPS will remain separate. The neutral line will be common for both EB and UPS. In the above scenario, the phase and neutral connections will be as follows: The UPS or EB phase is connected to P1, providing power to the device. The UPS or EB phase is also connected to P2 (looped from P1), providing power to the high load (H). The common neutral will be connected to N.
  • Type 2: Additional Customization for High Load Output Using External Relay (Common Neutral): The phases for EB and UPS will remain separate. The neutral line will be common for both EB and UPS. In the above scenario, the phase and neutral connections will be as follows: The UPS or EB phase is connected to P1, providing power to the device. The UPS or EB phase is also connected to P2 (looped from P1), providing power to the high load (H). The common neutral will be connected to N. To externally control high loads through an existing power switch (e.g., from H, 6A), add a 40A relay for external supply control. In the above scenario, the connections for the relay will be as follows: The phase for the relay is from H. The relay IN is directly connected from the DB phase. Then the relay OUT is connected to the AC load. The common neutral (N) will be connected for both the relay and the AC load. Note: Implement this solution only with accurate information from the official technical support team.
In the box
  • Touch Switch 1S × 1
  • Remote × 1
  • Console Screws × 2
  • Instruction Manual × 1
Warranty

3 years

  • Iotics Technology Private Limited undertakes to replace or repair, at its discretion, products should they become defective solely as a result of any manufacturing defects for a period of 3 years from the date of purchase.
  • The guarantee will be valid only if installation procedures / maintenance is carried out by a qualified professional electrician and the product has been used in a specific way and for the specified purposes as mentioned in the user's manual.
  • Loss or damages resulting from unauthorized adaptations/adjustments/tampering/improper installation of the product are not covered.
  • Accidental/Physical/Water damages and damages due to High Voltage burnouts are out of the purview.
  • Manufacturer takes no direct, indirect or any type of consequential liability of whatsoever nature under any condition, of customer's appliances functioning or malfunctioning of his/her appliance by or after buying the product.
  • The guarantee does not extend to cover consequential loss or damage or installation cost arising from the defective product.
Safety
  • Do not install the device without turning off the main power supply.
  • Do not connect the glass panel without turning off the main power supply.
  • Do not connect any load greater than 16A. Each light switch is rated to 16A resistive only.
  • Do not connect loads in series to one light switch.
  • This device is not suitable for single phase motor pumps as the starting current is 6 times that of the rated load current, which may cause relay contacts to permanently weld.
  • Take extra precaution while connecting phase and neutral wires to the device and the load.