Specs, wiring & warranty — 2 Switch

Technical specifications
ColoursBlack, White, Blue & Grey.
Power SourceAC 240V 50Hz
Module2 (2 Switches)
Max Load (Switch)GLS & Halogen Max.200W, LED & CFL Max.40W
Max Load (High load Switch)AC Upto 2000W (~2 Ton AC with EER > 3.5)
Self Consumption~1.6W
Wireless StandardIEEE 802.11 b/g/n
Operating Temp-10°C to +55°C
Dimension88mm x 88mm x 43mm
Enclosure MaterialABS (FR Grade)
Net Weight0.19kg
Remote control distance22 ft
Wiring drawing
Wiring drawing for 2 Switch
TerminalMeaning
NNeutral
PPhase UPS/EB
LLight
HHigh-Load
  • Type 1: Single Power Source (EB or UPS and Common Neutral): The phases for EB and UPS will remain separate. The neutral line will be common for both EB and UPS. In the above scenario, the phase and neutral connections will be as follows: The UPS or EB phase is connected to P, providing power to the device and two loads(L, and H). The common neutral will be connected to N.
  • Type 2: Additional Customization for High Load Output Using External Relay (Common Neutral): The phases for EB and UPS will remain separate. The neutral line will be common for both EB and UPS. In the above scenario, the phase and neutral connections will be as follows: The UPS or EB phase is connected to P, providing power to the device and two loads(L, and H). The common neutral will be connected to N. To externally control high loads through an existing power switch (e.g., from L, 6A), add a 40A relay for external supply control. In the above scenario, the connections for the relay will be as follows: The phase for the relay is from L. The relay IN is directly connected from the DB phase. Then the relay OUT is connected to the AC load. The common neutral (N) will be connected for both the relay and the AC load. Note: Implement this solution only with accurate information from the official technical support team.
In the box
  • Touch Switch 2S × 1
  • Remote × 1
  • Console Screws × 2
  • Instruction Manual × 1
Warranty

3 years

  • iotics Technology Private Limited undertakes to replace or repair, at its discretion, products should they become defective solely as a result of any manufacturing defects for a period of 3 years from the date of purchase.
  • The guarantee will be valid only if installation procedures / maintenance is carried out by a qualified professional electrician and the product has been used in a specific way and for the specified purposes as mentioned in the user's manual.
  • Loss or damages resulting from unauthorized adaptations/adjustments/tampering/improper installation of the product are not covered.
  • Accidental/Physical/Water damages and damages due to High Voltage burnouts are out of the purview.
  • Manufacturer takes no direct, indirect or any type of consequential liability of whatsoever nature under any condition, of customer's appliances functioning or malfunctioning of his/her appliance by or after buying the product.
  • The guarantee does not extend to cover consequential loss or damage or installation cost arising from the defective product.
Safety
  • Do not install the device without turning off the main power supply.
  • Do not connect the glass panel without turning off the main power supply.
  • For Loads L, Do not connect loads greater than 6A. Each light switch is rated up to 6A resistive only.
  • For Load H, Do not connect loads greater than 16A. Each High Load switch is rated up to 16A resistive only.
  • Take extra precaution while connecting phase and neutral wires to the device and the load.
  • Do not connect loads in series or in parallel to one 6A light switch. Only connect single light or single fan loads to each 6A switch.
  • Only a single load (6A) with a maximum of 40W is supported in cases of LED & CFL fitting. Anything more may weld the switch contacts and leave the load in a permanently ON state.
  • 12V And 24V power supply based LED light strips are NOT supported in 6A light switches. 240V Mains Voltage LED Strip Lights are supported in 6A light switch.