Back to Curtain Controller

Specs, wiring & warranty — Curtain Controller

Technical specifications
ColoursBlack, White, Blue & Grey
Power SourceAC 240V 50Hz
Module2 (Curtain Controller)
Max Load (Curtain)Single Channel Curtain Controller
Self Consumption~1.6W
Wireless StandardIEEE 802.11 b/g/n
Operating Temp-10°C to +55°C
Dimension88mm x 88mm x 43mm
Enclosure MaterialABS - FR Grade
Remote Distance22 ft
Wiring drawing
Wiring drawing for Curtain Controller
TerminalMeaning
NNeutral
PPhase UPS/EB
L1, L2Curtain motor: L1 forward (open), L2 reverse (close)
  • Type 1: Single Power Source (EB or UPS and Common Neutral): The phase and neutral for the curtain controller are from EB or UPS. In this scenario, the phase and neutral connections will be as follows: The UPS or EB phase is connected to P, providing power to the device. L1 is connected to the curtain open (Forward) terminal. L2 is connected to the curtain close (Reverse) terminal. The neutral is connected to N.
In the box
  • Curtain controller × 1
  • Remote × 1
  • Console Screws × 2
  • Instruction Manual × 1
Warranty

3 years

  • iotics Technology Private Limited undertakes to replace or repair, at its discretion, products should they become defective solely as a result of any manufacturing defects for a period of 3 years from the date of purchase.
  • The guarantee will be valid only if installation procedures / maintenance is carried out by a qualified professional electrician and the product has been used in a specific way and for the specified purposes as mentioned in the user's manual.
  • Loss or damages resulting from unauthorised adaptations/adjustments/tampering/improper installation of the product are not covered.
  • Accidental/Physical/Water damages and damages due to High Voltage burnouts are out of the purview.
  • Manufacturer takes no direct, indirect or any type of consequential liability of whatsoever nature under any condition, of customer's appliances functioning or malfunctioning of his/her appliance by or after buying the product.
  • The guarantee does not extend to cover consequential loss or damage or installation cost arising from the defective product.
Safety
  • Do not install the device without turning off the main power supply.
  • Do not connect the glass panel without turning off the main power supply.
  • For Loads L1 and L2 only the motor forward and reverse connections can be given. Take extra precaution while connecting phase and neutral wires to the device and the load.