Back to 2 Plug

Specs, wiring & warranty — 2 Plug

Technical specifications
ColoursBlack, White, Blue & Grey.
Power SourceAC 240V 50Hz
Module8 (2 Plugs)
Max Load (Plug)Max.500W
Self Consumption~1.6W
Wireless StandardIEEE 802.11 b/g/n
Operating Temp-10°C to +55°C
Dimension247mm x 88mm x 43mm
Enclosure MaterialABS (FR Grade)
Net Weight0.5 kg
Remote control distance22 ft
Wiring drawing
Wiring drawing for 2 Plug
TerminalMeaning
NNeutral
E1, E2Earth
P1Phase 1 UPS/EB
P2, P3Phase 2-3 EB
  • Type 1: Two Power Sources (EB + UPS and Common Neutral): The phases for EB and UPS will remain separate. The neutral line will be common for both EB and UPS. In the above scenario, the phase and neutral connections will be as follows: The UPS phase is connected to P1, providing power to the device. The EB phase is connected to P2, providing power to the plug and ensuring an earth point (E) is connected for the plug. The UPS phase is connected to P3, providing power to the plug and ensuring an earth point (E) is connected for the plug. The common neutral will be connected to N.
  • Type 2: Common Phase (EB or UPS and Common Neutral): The P1, P2, and P3 phases share the same phase line, either from the EB or UPS. The P1 phase is the primary power supply. Establish a loop connection from the P1 phase to the P2 and P3 phases to create a common phase line. In this scenario, the phase and neutral connections will be as follows: The EB or UPS phase is connected to P1, providing power to the device. The P1 phase is looped to P2, supplying power to the plug, and ensuring an earth point (E) is connected for the plug. The P1 phase is looped to P3, supplying power to the plug, and ensuring an earth point (E) is connected for the plug. The common neutral will be connected to N.
  • Type 3: Common Phase(EB or UPS) but different Load Capacity: The P1, P2, and P3 phases share the same phase line but have different load capacities, such as 6A and 16A, respectively. The P1 phase is the primary power supply. In this scenario, the phase and neutral connections will be as follows: P1 is responsible for 6A load variants. The EB or UPS phase is connected to P1, providing power to the device. The P1 phase is looped to P3, supplying power to the plug and ensuring an earth point (E) is connected for the plug. P2 is responsible for 16A load variants. The EB phase is connected to P2, supplying power to the plug, and ensuring an earth point (E) is connected for the plug. The common neutral will be connected to N.
In the box
  • Touch Switch 2P × 1
  • Remote × 1
  • Console Screws × 4
  • Instruction Manual × 1
Warranty

3 years

  • iotics Technology Private Limited undertakes to replace or repair, at its discretion, products should they become defective solely as a result of any manufacturing defects for a period of 3 years from the date of purchase.
  • The guarantee will be valid only if installation procedures/maintenance is carried out by a qualified professional electrician and the product has been used in a specific way and for the specified purposes as mentioned in the user's manual.
  • Loss or damages resulting from unauthorized adaptations/adjustments/tampering/improper installation of the product are not covered.
  • Accidental/Physical/Water damages and damages due to High Voltage burnouts are out of the purview.
  • Manufacturer takes no direct, indirect or any type of consequential liability of whatsoever nature under any condition, of customer's appliances functioning or malfunctioning of his/her appliance by or after buying the product.
  • The guarantee does not extend to cover consequential loss or damage or installation cost arising from the defective product.
Safety
  • Do not install the device without turning off the main power supply.
  • Do not connect the glass panel without turning off the main power supply.
  • For Socket, Do not connect loads greater than 6A. Socket is rated up to 6A resistive only.
  • Take extra precaution while connecting phase and neutral wires to the device and the load.