Install the controller — Water Level Controller
Before you start
- For one single-phase (1Φ) motor up to 1 HP only. It cannot be used with a DOL starter or a 3-phase motor.
- Have a qualified electrician install it. Switch off the main power supply before you start.
- You need the controller, the 4 float sensors, the console screws and a flat-head screwdriver.
- Cable: 2 runs of 4-core cable, one for the tank sensors and one for the sump sensors.
- Only a water tank and no sump? Contact support for the right wiring before you install.
- Stuck on this step? WhatsApp us a photo

Check what's in the box
You get the controller, 4 float sensors with 2 m wires, console screws and the instruction manual.
- Stuck on this step? WhatsApp us a photo
Switch off the power
Switch off the main power supply. Keep it off until all the wiring is done.
- Stuck on this step? WhatsApp us a photo
Mount the controller
Wall-mount the controller near the motor pump switch or starter, at a comfortable height for checking and maintenance.
Choose a dry, well-ventilated place close to the power supply. Keep it away from rain, water splashes and direct sunlight.
- Stuck on this step? WhatsApp us a photo
Place the tank sensors
Put the tank low sensor at about 25% of the tank capacity and the tank high sensor at about 90%. Tape them in place.
You can adjust these levels to suit your tank.
- Stuck on this step? WhatsApp us a photo
Place the sump sensors
Put both sump sensors in the sump, 2–10 inches apart, just above the sump's foot valve. Tape them in place.
With a submersible pump, place them over the pump's intake valve.
- Stuck on this step? WhatsApp us a photo
Run the sensor cables
Each sensor has two wires. Extend them to the controller with one 4-core cable for the tank and one for the sump.
- Stuck on this step? WhatsApp us a photo

Connect the tank sensors
At the Overhead Tank terminals, connect the tank low sensor to C and BS, and the tank high sensor to C and TS.
Sensors connect only to the controller. Never connect them to the 240V AC mains.
- Stuck on this step? WhatsApp us a photo

Connect the sump sensors
At the Underground Sump terminals, connect the lower sump sensor to C and BS, and the upper sump sensor to C and TS.
- Stuck on this step? WhatsApp us a photo

Connect the power and the motor
Connect the single-phase supply phase to P and neutral to N. Connect the motor between L and neutral.
Connect it in parallel with your motor switch or starter, so you can still run the motor by hand.
- Stuck on this step? WhatsApp us a photo
Switch on and test